$ 574.72
Teomics proudly introduces SlideMaster, a humidity chamber designed by a histotechnologist that eliminates the majority of individual slide handling.
SlideMaster has three different parts: a humidity chamber, two individual slide holders with white contrast bars, and a waste receptacle. It has been designed so that all three components are compact and easy to use. A maximum of 20 slides can be used per unit.
To use, a hydrophobic barrier is drawn around the tissue section and slides are put in a special slide holder that secures them into place. Drops of antibody are placed on the slides and incubated. After incubation, the individual slide holders can be tilted and secured at a 45 degree angle. All 20 slides are rinsed off in one easy motion and the buffer drains into the waste receptacle. Slides are gently blotted (tissue paper) at the bottom portion of the hydrophobic barrier, which draws off any remaining liquid on the tissue.
The slide holders are then placed back in the horizontal position and incubation and rinse steps are repeated in the same fashion. For chromogen development, the SlideMaster unit has a contrast bar that changes the background from black to white. The black background produces high contrast so that the tissues mounted glass slides can be easily seen, and the white background produces high contrast and allows the technician to monitor the chromogen development. Slides are then rinsed and counterstained and are then ready for coverslipping. SlideMaster is very easy to use. It is light weight and durable. By making the hydrophobic barrier around the tissue section as small as possible, the total volume of antibody reagent can be significantly reduced per slide. Instead of using 100-200 microliters of antibodies per tissue section usually 50 microliters will completely cover small tissues and 100 microliters will cover larger tissues. With this method, slide staining is much more efficient, more consistent, drying-out of slides is minimized, and the cost of reagents is reduced.
$ 104.60
Each SlideFile Storage System includes a slide box and a removable tray. A tinted hinged cover makes the contents of the box easy to see at a glance.The base is available in five different colors to help in slide classification and to minimize the possibility of sample mix-up. The key to the SlideFile System is a removable tray inside the storage box having a hundred individual numbered slots. All slides are stored upright for easier insertion and removal. Simply tilt them forward and backward with one finger to easily and rapidly pick up the slide you need. A unique feature with this system is to be able to read bar codes without having to remove the slides from the box. For space saving purposes, you can double the amount of slides simply by storing two slides per slot. For maximum storage space, simply remove the tray and line up 400 slides in 3 rows for long term storage. Will resist temperatures between -80 C and +80 C. Not autoclavable.
Dimensions
82 x 245 x 86 mm H (3 1/4 x 9 5/8 x 3 3/8 in. H)
$ 277.37
Made of ABS Plastic
Simplify your workflow with this user-friendly approach to immunohistochemistry staining. It will accept up to 20 slides on four plastic rails covered with a polymer strip to perfectly hold slides even if tray is held at an angle. When humidity is needed, wells between rails will hold up to one ml of water securely without splashing. The middle wells will hold up to 2 ml each. Rails are raised not only to avoid water touching the slides but to make them more easily retrievable. The base will also hold excess stain solution dripping from the slides. Four rubber feet ensure greater base stability. Units are stackable for space saving purposes. This tray is also suitable not only for routine staining requiring a humid chamber, but is also ideal for Hematology, Cytology and Microbiology laboratories. Manipulation is made safe and easy by using only one hand.
The StainTray has a black base made of tough ABS plastic withstanding a wide range of chemicals (avoid chlorinated hydrocarbons ).
Two covers are available:
Dimensions with cover: 38 W x 24 D x 4.5 H cm (15 W x 9 3/8 D x 1 3/4 H in.)
$ 107.00
Toluidine Blue Solution is designed for metachromatic staining of acidic substances.
$ 89.00
The positive control slides are intended to be used to verify histological techniques and reagent reactivity and are not intended to be used for any quantitative purpose.
Tissues are human, formaldehyde-fixed, paraffin-embedded, heat dried and cut at 5 microns unless otherwise specified. Standard tissue placement is mid-range of the slide.
$ 134.00
Tris-EDTA HIER Solution (10x) pH 9.0 is a unique buffer designed to significantly enhance immunohistochemical staining with many commercially available primary antibodies. Diluted 1:10 with deionized or distilled water, this product is easy to use and highly effective.
$ 146.00
Our stabilized trypsin-based antigen retrieval solution is simple to use; a tissue section is incubated 10 minutes at 37 deg. centigrade in this two component, ready-to-use solution. This product is stable for 9 months at 2-8 deg centigrade. This product contains 30 or 60 ml of trypsin concentrate, and 125 or 250 ml of buffer.
$ 68.00
This solution is a component in Fite's Acid-Fast stain for leprosy organisms.